top of page
ASD.jpg

Aspiration Smoke

Detection System

AVA Aspiration Smoke
Detection System

Aspirating smoke detection (ASD) systems are quite different from traditional point-type smoke detectors. A typical aspirating detection system is comprised of a number of pipes laid out above or below a ceiling in parallel runs, some meters apart. Small holes, also some meters apart, are drilled into each pipe to form a matrix of holes ('sampling points'), providing an even distribution across the ceiling. Air or smoke is drawn into the pipework through the holes and onward to a very sensitive smoke detector mounted nearby, using the suction pressure of an aspirator. For a specific object or cabinet protection, the sampling points can be fed into and around the equipment with flexible capillary tubes. When high air-flow movement is presence in the protection area like data centre or cleanrooms, the sampling points can be located in the return air path to intercept the smoke.

Actually the configuration of the sampling pipework’s and sampling points is very flexible. Compared with the traditional way to install point type smoke detector on the ceiling, the aspirating detection systems can be installed in any place where the fire or smoke presents.

 

Applications:

Warehouses, large halls & High roof areas

Data centres, clean rooms & cold rooms

laboratory and research centres

Cable and energy tunnels

Transformer rooms - High- and low-voltage distribution cabinets

High Risk Equipment’s

Museums, galleries, theatres and cinemas

Production facilities

Railways, Airports, underground car parks

Electronic measurement rooms - EDP racks, telecommunications facilities

Historical buildings

QUARTAS  SERIES

Very Early Warning

Aspiration Smoke Detector

product.jpg
Anchor 1
1_edited.jpg

QUARTAS-500s
Single Pipe Aspirating
Smoke Detector

Max. no. of Sampling Holes

  • Class A - 40

  • Class B - 60

  • Class C - 60

 Max. Sampling Pipe Length

  • Single Pipe - 100m 

  • Two Brached Pipe - 2 x 80m

  • Four Branced Pipe - 4 x 60m

QUARTAS-2000s
Four Pipes Scanning
Aspirating Smoke Detector

Max. no. of Sampling Holes

  • Class A - 40

  • Class B - 60

  • Class C - 100

 Max. Sampling Pipe Length

  • Single Pipe - 4 x 100m  

  • Two Brached Pipe - 4 x 2 x 80m

2.jpg
1.jpg

QUARTAS-500s

Single Pipe
Aspirating Smoke Detector

2.jpg

QUARTAS-2000s

Four Pipes Scanning
Aspirating Smoke Detector

QUARTAS-2000s Pipe Scan

Taking advantage of the four individual aspirators in the QUARTAS-2000s, in case of fire it can turn on and off each aspirator in sequence to “identify” the pipe having the most smoke.

BLUE LED DETECTION

â–º High Power Blue LED Light Source

â–º Wide Angle Nephelometer Mass Detection

â–º Maximum  Detection  Sensitivity 0.001%/m

â–º Maximum Alarm Sensitivity 0.005%/m

SSL Artificial Intelligent Smart Smoke Level

â–º No False Alarm
 

â–º Constant Level of Protection
 

â–º Easy to Observe Abnormal

â–º Easy for Commissioning

ssl_edited.jpg

MULTIPLE FUNCTION DISPLAY/ PROGRAMMER

â–ºDisplay
 

  • Smoke, Flow, Address, Event/Error Code
     

  • 20 Segments Smoke Bargraph
     

  • Alarm and Fault Indicators

 

â–º Control
 

  • ​Reset/Isolate/Silence/Test Buttons

 

â–º Programmer

QUARTAS-500s

Tyipical Applications

  • Internet Data Center

  • Computer Room

  • Telecom Room

  • Control Room

  • Electrical Room

  • Air Conditioning Facilities

  • Cleanrooms

  • Railway Coach

  • ESS Energy Storage System 

54be2ed4-fcad-45f9-92c1-ac6ad3977bd7.jpg
quartas_2000-.jpg

QUARTAS-2000s

Tyipical Applications

  • Warehouse/High Bay Wareshouse

  • Distribution Center

  • Airport

  • Transportation Station

  • Museum/Gallary

  • Cleanrooms

  • Electrical Room 

bottom of page